MBS-Diaphragm MMR

The diaphragms MMR got used in association with SMR top jaws on diaphragm-chucks without through bores (MBS-L, MBS-Z) or vices (MBS-N). The top jaws got screwd in from the backside on the diaphragms. This has the advantage that no bores at all are existing in range of the clamping diameter, which could disturb a more exact clamping result.

spannmembrane

Order-No. For chuck sizes Number of jaws D H Weight kg
MMR-080-6 80 6 81,0 14,0  
MMR-100-6 100 6 102,0 18,0  
MMR-125-6 125 6 127,0 18,0  
MMR-150-6 150 6 152,0 17,7  
MMR-200-6  200 6 204,0 17,5  
MMR-250-6 250 6 254,0 22,0  
MMR-300-6 300 6 294,0 24,5  
  • The diaphragm is also available with another number of jaws on request.

MBS-Diaphragm MMK

The diaphragms MMK got used in association with SMK top jaws on diaphragm-chucks without through bores (MBS-L, MBS-Z) or vices (MBS-N). The top jaws got screwd in from the front on the diaphragms, this grants a fast change-over of the top jaws.

spannmembrane

Order-No. For chuck sizes Number of jaws D H Weight kg
MMK-080-3 80 3 81,0 14,0  
MMK-100-3 100 3 102,0 18,0  
MMK-125-3 125 3 127,0 18,0  
MMK-150-6 150 6 152,0 17,7  
MMK-200-6  200 6 204,0 17,5  
MMK-250-6 250 6 254,0 22,0  
MMK-300-6 300 6 294,0 24,5  
  • The diaphragm is also available with another number of jaws on request.

MBS-Diaphragm MDR

The diaphragms MDR got used in association with SDR top jaws on diaphragm-chucks without through bores (MBS-DL, MBS-DZ). The top jaws got screwd in from the backside on the diaphragms. This has the advantage that no bores at all are existing in range of the clamping diameter, which could disturb a more exact clamping result.

durchlassmembrane

Order-No. For chuck sizes Number of jaws D H Weight kg
MDR-125-6 125 6 127,0 18,0  
MDR-150-6 150 6 152,0 17,7  
MDR-200-6  200 6 204,0 17,5  
MDR-250-6 250 6 254,0 22,0  
MDR-300-6 300 6 294,0 24,5  
  • The diaphragm is on request also available with another number of jaws.
MicroCentric GmbH
MicroCentric GmbH
Ringstrasse 134
70839 Gerlingen



Tel.: 0049 (0)7156 17819-0
Fax: 0049 (0)7156 17819-20
E-Mail: info@microcentric.de

  • Imprint
  • AGB
  • Privacy
© 2025 MicroCentric GmbH. All Rights Reserved.
  • Products
  • Company
  • Contact
    • Worldwide contacts
    • Contact form
  • Downloads